Our fascia panels and mimic diagrams are produced using the same materials and process as our plant labels with the additional of "cut-outs".

Cut-outs are holes or shapes cut through the entire thickness of the material, this allows the mounting of components such as selector switch's and indicator lamps. Cut-outs can be any shape or size, from simple circles, squares and rectangles to more complex shapes such as a component requiring a key way.

All cut-outs are machined with a tolerance of +/- 0.1mm to ensure a perfect fit for the component being mounted.

We can supply our fascia panels and mimics with a number of fixings methods allowing for easy installation, these include fixing holes of any diameter, high performance double sided tape, a combination of fixing holes and double sided tape or even magnetic.

When a more complex mimic or flow line diagram is required we are able to accept AutoCAD .dwg and .dxf files which can be imported directly into our software to save set-up time and costs.